WallFlex™

Esophageal Stents (including Benign Indication)

Available in fully and partially covered options
Permalume™ Silicone Coating is designed to minimize tumor ingrowth and help reduce food impaction
Progressive step flared ends may assist in anchoring the stent within the esophageal lumen
Low profile delivery system designed to traverse tight strictures

Boston Scientific stent technology is built on science and innovation to expand options available for patient treatment and management.

Explore

Product Details

Building on the best of Boston Scientific’s industryleading stents, the WallFlex Stent seeks to deliver luminal patency through a combination of flexibility and control to support your goal of optimized patient care.

The WallFlex Esophageal Stent is available in fully and partially covered options and avariety of lengths and widths.

WallFlex Esophageal Stent Details

Migration Resistance
The Progressive Step Flared Ends may assist in anchoring the stent within the esophageal lumen.

Stricture Resolution
The multiple wire braided construction is engineered to allow the WallFlex Esophageal Stent to adjust to forces from the esophageal anatomy such as strictures and peristalsis. The design allows for gradual stent expansion, which is typically complete after 24-72hrs.

Tissue InGrowth Prevention
The Permalume™ Silicone Covering extends the entire length of the WallFlex Esophageal Stent in the fully covered version and is designed to prevent tumor ingrowth as well as stent concurrent esophageal fistulas.

Removability & Adjustability
The Coated Polyester Removal Suture facilitates removal during the initial stent placement procedure.

Fluoroscopic Visualization
The Nitinol construction allows for clear visualization during fluoroscopy, ensuring accurate stent placement.

Delivery System Details

Pre-dilation Avoidance
The 18.5 French (6.2mm), low profile delivery system is designed to traverse tight strictures.*

Endoscopic Placement
The Endoscopic Transition Zone is designed to aid in stent placement accuracy when deployed using endoscopic visualization.

Stent Placement Accuracy
The coaxial delivery system is designed to result in 1:1 stent deployment.

The fully covered stent may be reconstrained up to 75% of deployment and 2 times during the initial stent placement procedure.**

* Predilation may not be required, depending on stricture lumen diameter.
** A stent can not be reconstrained after the reconstrainment limit has been exceeded.

Ordering Information

WallFlex™ Esophageal Stents

Building on the best of Boston Scientific’s industry-leading stents, the WallFlex™ Stent seeks to deliver luminal patency through a combination of flexibility and control to support your goal of optimized patient care. The stent is available in fully and partially covered options and a variety of lengths and widths.

WallFlex Fully Covered Esophageal Stent
WallFlex™; Fully Covered Esophageal Stent*
WallFlex Fully Covered Esophageal Stent*
Order NumberStent O.D. (mm)Proximal / Distal Flares O.D. (mm)Stent Length (cm)Catheter Diameter (Fr / mm)System Length (cm)
M005162101825 / 231018.5 / 6.17120
M005162201825 / 231218.5 / 6.17120
M005162301825 / 231518.5 / 6.17120
M005162402328 / 281018.5 / 6.17120
M005162502328 / 281218.5 / 6.17120
M005162602328 / 281518.5 / 6.17120
WallFlex Partially Covered Esophageal Stent
WallFlex™ Partially Covered Esophageal Stent*
WallFlex Partially Covered Esophageal Stent*
Order NumberStent O.D. (mm)Proximal / Distal Flares O.D. (mm)Stent Length (cm)Covered Length (cm)Catheter Diameter (Fr / mm)System Length (cm)
M005169001823 / 2310718.5 / 6.17120
M005169101823 / 2312918.5 / 6.17120
M005169201823 / 23151218.5 / 6.17120
M005169302328 / 2810718.5 / 6.17120
M005169402328 / 2812918.5 / 6.17120
M005169502328 / 28151218.5 / 6.17120

*Recommended Guidewire .038" Jagwire™ Guidewire, Order #5662, (see below).

1 Product with this symbol may be used in Magnetic Resonance environment according to the conditions described in Directions for Use.

     

 

 