Captivator™ II

Single-Use Snare

The rounded shape of the Captivator II snare is designed to capture flat lesions and has a shorter distance from the scope to facilitate tip control and visualization.
Provides a variety of size options to help manage different polyp types
Smaller loop options help with the removal of diminutive polyps and the resection of residual tissue during EMR
The stiff braided wire design provides grip and traction on flat polyps and allows for wire control.
All of Boston Scientific’s snares are now indicated for both cold and hot polypectomy.

The Captivator II Snares are the first line of stiff and rounded snares, with hot and cold snaring indications. A variety of size options help manage different polyp types.

Explore

Product Details

The Captivator II Snare line provides a variety of size options to help manage different polyp types such as large or flat lesions, lesions on the right-side of the colon and lesions on a colonic fold.

The Captivator II Snares are the first line of stiff and rounded snares, available in multiple sizes with both a hot and cold snaring indication.

Features include:                    

  • Stiff Snare
  • Rounded Shape
  • Braided Wire
  • Hot/Cold Indication
  • Smaller Loop Options

 

For more information on product, please download our product brochure.

Ordering Information

Captivator II Single-Use Snare
Captivator II Single-Use Snare
Order NumberDescriptionLoop Width (mm)Sheath O.D. (mm)Minimum Working Channel (mm)Working Length (cm)Packaging
M0056122110mm Rounded - Stiff
102.42402.8Box 10
M0056122210mm Rounded - Stiff102.42402.8Box 20
MOO56122310mm Rounded-Stiff102.42402.8Box 40
M0056123115mm Rounded - Stiff152.42402.8Box 10
M0056123215mm Rounded - Stiff152.42402.8Box 20
MOO56123315mm Rounded-Stiff152.42402.8Box 40
M0056124120mm Rounded - Stiff202.42402.8Box 10
M0056124220mm Rounded - Stiff202.42402.8Box 20
MOO56124320mm Rounded-Stiff202.42402.8Box 40
M0056119125mm Rounded - Stiff252.42402.8Box 10
M0056119225mm Rounded - Stiff252.42402.8Box 20
MOO56119325mm Rounded-Stiff252.42402.8Box 40
M00561291Extra Large Rounded Stiff332.42402.8Box 10

Case Studies


Case Study: Endoscopic Mucosal Resection (EMR)

Presented by David A. Florez, MD (USA)

This case demonstrates the management of large polyps utilizing the Captivator II Snare.  The large diameter aperture of the snare allows for complete en-bloc resection of the polyp with one pass.