Habib™

EndoHPB Bipolar Radiofrequency Catheter

Habib Animation in Stricture
Habib™ EndoHPB Catheter and Adaptor
Habib™ EndoHPB Catheter used with the SpyGlass™ DS System
Habib™ EndoHPB Bipolar Radiofrequency Catheter
Habib™ EndoHPB Bipolar Radiofrequency Catheter
Habib™ EndoHPB Bipolar Radiofrequency Catheter
Biliary metal stent placement along with Habib™ EndoHPB RF ablation may provide prolonged stent patency1.
Habib™ EndoHPB Catheter and Adaptor is compatible with most electrosurgical generators and potentially eliminates additional capital investment.
Use of the SpyGlass™ DS System for direct visualization before or after ablation with the Habib™ EndoHPB Catheter aid in targeted ablation of the lesion and decompression of biliary ducts and help to confirm efficacy of ablation size and location.
Habib™ EndoHPB Bipolar Radiofrequency Catheter
Habib™ EndoHPB Bipolar Radiofrequency Catheter
Habib™ EndoHPB Bipolar Radiofrequency Catheter

The Habib™ EndoHPB Catheter is the first Radio Frequency (RF) ablation catheter indicated in Europe for malignant or benign tissue ablation in the pancreatic and biliary tract.

When surgery is not an option for patients with difficult-to-treat cancers, the Habib™ EndoHPB Catheter enables you to perform:
• Partial or complete ablation of malignant or benign tissue in the pancreatic and biliary tracts.
• Endoscopic biliary drainage or decompression prior to stent placement or afterwards to clear an occluded stent.

Endoscopic biliary RF ablation with the HabibTM EndoHPB Catheter may provide prolonged stent patency. One study has shown prolonged metallic biliary stent patency by an average of 13% (from 8.4 months to 9.5 months)1 in patients with unresectable extrahepatic cholangiocarcinoma.

Key Resources

Explore

Product Details

Device Specification Intended Benefits 
180cm useable length, 8Fr (2.7mm) diameterEnables biliary access through a 3.2mm working channel duodenoscope
2, 8mm stainless steel ring electrodesProduce ablation depths 3-4mm from the wall of the catheter. Resulting ablation zone is 25mm ± 3mm long by 9mm ± 2mm wide (1)
Compatible with commonly available RF generators and endoscopes with a working channel of 3.2mm or greaterDoes not require the purchase of dedicated capital equipment
Bipolar RF DeviceUse of adapter cable enable bipolar RF ablation and avoids the need for electrode grounding pads

Features and Benefits

  • Treatment alternative that may prolong patency and restore biliary drainage1
  • The Habib EndoHPB Catheter may provide an option to restore biliary drainage in patients who may outlive the patency of their metallic biliary stents.2
  • Clinical data from one study suggests that RFA with the Habib EndoHPB Catheter for occluded SEMS may improve mean stent patency time compared to plastic stent insertion.2

Minimal Capital Investment

The Habib™ EndoHPB Catheter is compatible with many commonly available electrosurgical generators and endoscopes with a working channel of 3.2mm or greater, eliminating the unique capital expenditure. There is also no need for electrode grounding pads when using our adaptor cable.

UPNDescriptionGenerator
M00500070EndoHPB Bipolar Radiofrequency CatheterN/A
5100Adapter Cable Bipolar, 28mm pinsKLS Maxium, Olympus ESG-100
5420Adapter Cable Bipolar,  Internal 4 mm pinErbe ICC200, ICC300, ICC355, Erbe Vio 200 or 300 (D/S) Genii GI 4000
5700Adapter Cable Bipolar, 22 mm SpacingErbe ICC200, ICC300, ICC355, Erbe Vio 200 or 300 (D/S)  

Ease of Use

  • No need for dedicated capital equipment
  • Compatible with most electrosurgical generators
  • Simple time and power algorithm delivers consistent results3
  • One probe size, each ablation produces an ablation zone approximately 25mm x 3.5mm deep (at 10W, 90s).3

 

Ordering Information

Product NumberProduct DescriptionSpecifications
M00500070Habib EndoHPB Bipolar RF Catheter (180cm, 8F)Single-Use
5420Bipolar Adapter CableReusable
5100Bipolar Adapter CableReusable
5420Bipolar Adapter CableReusable
5700Bipolar Adapter CableReusable
Pricing is subject to change without notice.
 

Contact Information and Ordering

For product orders or complaints, please contact: 1-888-272-1001

 