Acquire™ S
Endoscopic Ultrasound Fine Needle Biopsy (FNB) Device
Acquire S is designed for ease-of-puncture¹ and to help maximize diagnostic yield without compromising the quality of core tissue samples to obtain an accurate diagnosis.²
Explore
Product Details
Maximize Yield and Maintain Core Tissue Sample Quality
Rely on the benefits of the proven Franseen Needle to maximize diagnostic yield and maintain core tissue sample quality.2
Diagnostic Yield
Adequate diagnostic yield is critical to getting to a diagnosis and is playing an increasingly important role in oncology research and genomic sequencing to aid developing targeted cancer therapies.5 Based on more than 50 years of clinical use in interventional radiology6 and use in diagnostic EUS since 2016, the Franseen Needle design has a proven track record for diagnostic yield and accuracy.2
Histological Architecture
The Franseen needle has 3 symmetrical needle points with fully formed cutting heels3 that are electropolished for sharpness.4 End-cutting EUS needles may be preferred when larger histological specimens and preserved tissue architecture are required, which may aid in histologic processing.7
Designed for Ease of Puncture
- The Taper Point Stylet is designed for ease of puncture when performing EUS FNB.1 Benchtop testing has demonstrated utilization of the Acquire S Taper Point Stylet that offers a 36.6% reduction in puncture force as compared to leading with the Franseen 22ga needle (stylet back).1
- Bench testing of Acquire S with the Taper Point Stylet forward demonstrated equivalent puncture force to utilization of a fork tip EUS FNB needle.8
Stylet Features:
- The Taper Point Stylet geometry is designed to center the stylet point within the sheath during device passage in tortuous scope positions.9
- A white stylet clip is for identification of the Taper Point stylet system and a way to visibly distinguish it from the Acquire device.
- The Acquire S Taper Point stylet can be used in the advanced or retracted position for physician preference.
Case Studies
Case Study: Evaluation of a hypoechoic mass in the pancreatic tail region revealed to be adenocarcinoma
Case Study: Assessment of a nodular lesion in the duodenal bulb is suggestive of carcinoid tumor
Indications, Safety, and Warnings
Ordering Information
Product Code | GTIN | Description | Needle size (gauge) / (mm) | Minimum working channel (mm) | Sheath Diameter (mm) | Units |
---|---|---|---|---|---|---|
M00555640 | 00191506030742 | 22ga Acquire S EUS FNB Needle | 22/0.72 | 2.4 | 1.65 | Box 1 |
M00555660 | 00191506030759 | 25ga Acquire S EUS FNB Needle | 25/0.52 | 2.4 | 1.52 | Box 1 |
M00555641 | 00191506030766 | 22ga Acquire S EUS FNB Needle | 22/0.72 | 2.4 | 1.65 | Box 5 |
M00555661 | 00191506030773 | 25ga Acquire S EUS FNB Needle | 25/0.52 | 2.4 | 1.52 | Box 5 |