Skip to main content
Surgeon's gloved hands holding a medical device with wire.

EMBOLD™ Detachable Coil System case study

EMBOLD™ Fibered Coils treatment of an AVM​

In this case study, we explore the use of Embold Fibered Coils in the treatment of a complex pulmonary arteriovenous malformation (PAVM) situated within the right upper lobe, which was discovered during a routine head and neck CTA for headache. The medical team employed a 5 F diagnostic catheter to access the right pulmonary artery and subsequently used a TruSelect™ Microcatheter to facilitate the catheterization of the two pulmonary artery branches supplying the PAVM within the right upper lobe. Embold Fibered Coils were deployed into the feeding arteries without any movement, resulting in successful occlusion.

Presentation

Complex PAVM of the right upper lobe with multiple feeders. This was found incidentally on a head and neck CTA for headache.

Intervention

A 5 F diagnostic catheter was used to enter the right pulmonary artery. A TruSelect Microcatheter was subsequently utilized to catheterize two right upper lobe pulmonary artery branches supplying a pulmonary AVM. Embold Fibered Coils were successfully deployed precisely into only these feeding arteries. Both the microcatheter and coils tracked very easily without any movement during coil deployment.

Outcome

Embold Fibered Coils occluded the flow to this complex pulmonary AVM.

Scan of vein before placement of coil. AVM pre-procedure
Scan of vein after Embold fibered coil. After Embold Fibered placement​

Preston Eiswirth, MD​
Intermountain Medical Center​
Murray, UT​

Results from case studies are not necessarily predictive of results in other cases. Results in other cases may vary.