VersaCross Connect™ LAAC Access Solution

The VersaCross Connect LAAC Access Solution connects VersaCross™ technology with compatible WATCHMAN™ sheaths for zero exchange left heart access.

Configure or select a product to continue to order

Zero exchange delivery of WATCHMAN Access Systems*

The VersaCross Connect LAAC Access Solution connects VersaCross technology with WATCHMAN* sheaths for zero exchange left heart access.

VersaCross Connect Transseptal Dilator with 3-in-1 RF wire.

How it works

Discover how the 3-in-1 RF wire and transseptal dilator simplify left atrial appendage closure (LAAC) by connecting the VersaCross Connect Transseptal Dilator and WATCHMAN Access Sheath* for zero exchange left heart access


Why choose the VersaCross Connect LAAC Access Solution

All-in-one transseptal access solution designed for use with WATCHMAN Access Systems*

VersaCross Connect LAAC Access Solution with lines highlighting smooth transition between dilator and WATCHMAN Access Sheath.

Smooth transition

Smooth transition between VersaCross Connect Transseptal Dilator and WATCHMAN Access Sheath*

Snap-lock designed for WATCHMAN Access Sheaths.

Snap-lock

Snap-lock designed for WATCHMAN Access Sheaths*

Know where you are at all times with OMNIviz technology

Reliably locate the VersaCross Connect solution on fluoroscopy and ultrasound. Positional markers indicate position of RF tip within dilator. Connect to DuoMode Cable to track and mark RF tip on mapping system.

Fluoroscopic image of RF wire in sheath/dilator assembly.

What’s included

The VersaCross Connect LAAC Access Solution includes:

  • VersaCross RF Wire (j-tip or pigtail)
  • Single-use RFP-100A Connector Cable
  • VersaCross Connect Transseptal Dilator (12.5F) with TRUform™ shapeable technology
  • 0.035” guidewire

Required product

RFP-100A RF Puncture Generator.

Designed for controlled tissue puncture using radiofrequency energy



All trademarks are the property of their respective owners.

* The VersaCross Connect Transseptal Dilator is for use with a 12F (4.09 mm) ID WATCHMAN Access Sheath that is 75 cm in length or the WATCHMAN TruSteer™ Access Sheath that is 67 cm in length, specifically: WATCHMAN Access System [Models: M635TU40060, M635TU10060, M635TU20060]; WATCHMAN TruSeal™ Access System [Models: M635TU70010, M635TU70040, M635TU70020]; WATCHMAN FXD Curve™ Access System [Models: M635TU80010, M635TU80020]; WATCHMAN TruSteer Access System [Model: M635TU90050].

† Baylis Medical Company Radiofrequency Puncture Generator RFP-100A. Baylis Medical Company is a wholly owned subsidiary of Boston Scientific Corporation.