Benjamin W. Fischer-Valuck, M.D.a; Anupama Chundury, M.D.a; Hiram Gay, M.D.a; Walter Bosch, D.Sc.a,b; Jeff Michalski M.D., MBAa
b. Washington University Advanced Technology QA Center, St. Louis, Missouri
The purpose of this secondary analysis of the SpaceOAR Hydrogel U.S. Pivotal trial was to assess hydrogel distribution and its impact on rectal dose reduction during radiotherapy. The study included 149 patients with stage T1 or T2 prostate cancer, Gleason score ≤7, and a PSA ≤20 ng/mL who were planning to receive IG-IMRT.
A team of 3 radiation oncologists evaluated the postimplant T2-weighted MRI for all 149 patients and determined hydrogel symmetry using a semiqualitative scoring system. A score of Sym 1 recognizes hydrogel symmetry in all 3 slices (midgland, 1 cm superior and 1 cm inferior to midland). Scores 2–5 represent increasing asymmetry (see Figure 1 below). The symmetry was then correlated to rectal dose reduction using a Student t test.
Overall, a symmetrical spacer application was found in 92 (62%) of the midgland and superior axial slices, and 108 (72%) of the inferior slices. Seventy-three (49.0%) patients had spacer symmetry in all 3 axial slices, with 26 (17.4%), 20 (13.4%), 28 (18.8%), and 2 (1.3%) patients with scores of Sym 2 through Sym 5, respectively.
Conclusion: As previously demonstrated in the pivotal trial, SpaceOAR Hydrogel demonstrates significant reduction of rectal dose during IG-IMRT. In this study, asymmetry of hydrogel was found to be common; however, all but the most extreme asymmetry still resulted in significant rectal dose reductions.
Coronal view of the prostate with location of the midgland, superior (Sup), and inferior (Inf) axial slices evaluated. Also shown are symmetry locations, with 1 representing midline, 2L/2R representing 1 cm left and right, and 3L/3R 2 cm left and right, respectively.
Absolute rectal dose-volume histogram (DVH) for each Sym score group following spacer application.
Results from case studies are not necessarily predictive of results in other cases. Results in other cases may vary.
The content of this article/publication is under the sole responsibility of its author/publisher and does not represent the opinion of Boston Scientific Corporation.
CAUTION: US Federal law restricts this device to sale by or on the order of a physician.
CAUTION: The law restricts these devices to sale by or on the order of a physician. Indications, contraindications, warnings, and instructions for use can be found in the product labelling supplied with each device or at www.IFU-BSCI.com. Products shown for INFORMATION purposes only and may not be approved or for sale in certain countries. This material not intended for use in France.
All trademarks are the property of their respective owners.