AVVIGOTM+ Multi-Modality Guidance System

A leap forward in PCI technology*

*Compared to POLARIS technology

AVVIGO™+ Fast. Intuitive. Accurate.

AVVIGO+ is Boston Scientific's streamlined multi-modality guidance platform that is designed to enhance the intravascular imaging (IVUS) and physiology experience - Fractional Flow Reserve (FFR) / Diastolic Hyperemia-Free Ratio (DFR). Designed to be fast, intuitive and accurate, it integrates PCI guidance tools into one easy-to-use system, users across the cathlab can perform faster, more efficient procedures than before.


image

Automated Lesion Assessment (ALATM)

Automated Lesion Assessment (ALA) uses machine learning technology to automatically deliver visualization of vessel/lumen borders, key frame markers, and the vessel profile with a high degree of accuracy1. ALA not only helps to strategically plan out a case, but also allows physicians to override IVUS vessel measurements if necessary.


image BSC_FARAPULSE_Header_Images

Fast pullback

image

Automatic pullback now includes faster speeds up to 8mm/s compared to that of POLARIS, allowing for quicker vessel imaging without reducing image quality.

Side-by-side comparison of 0.5mm/s vs 8.0mm/s IVUS pullback

Note - Pullbacks are done for two different vessels.


image

PhysioMapTM

PhysioMap is designed to allow continuous DFR measurements across a vessel over time. Instead of manually measuring DFR values at different segments of the vessels, physicians can now pullback the COMET II pressure wire and the system will plot the DFR value over a trendline. This feature is helpful for identifying lesion types such as focal or diffuse lesions.


image

Tableside Control (TSC)

image

With an integrated AVVIGO+ system, TSC will now give the operator control of IVUS and Physiology measurements from a table mounted tablet covered by a sterile drape. The 15'' tablet has impressive touch response and still maintains its high quality images.


graph image quantitative vs qualitative analysis

AVVIGOTM+ Multi-Modality Guidance System

AVVIGO+ is designed to maximise user experience and patient outcomes.


Evolution of imaging

image

IVUS training and education

Gain access to a comprehensive suite of basic to advanced IVUS training modules exclusively on the EDUCARE platform.


graph image quantitative vs qualitative analysis

Request a rep

Fill out a quick form and one of our Cardiology sales representatives will be in touch to answer any questions you may have.

All trademarks are property of their respective owners.

 Bench Test results may not necessarily be indicative of clinical performance. Results from different clinical investigations are not directly comparable. Information provided for educational purposes only. Results from clinical studies are not predicative of results in other studies. Results in other studies may vary.

The information presented in this document by Boston Scientific is intended for healthcare professionals in India. [The information presented in this document is intended to provide balanced, scientific, and evidence based answers to unsolicited medical questions.] The information should not be, however, treated as comprehensive and does not intend to provide diagnosis, treatment or any medical or health advice. For full information about the product, please refer to the appropriate product labeling. Responsibility for patient care resides with the healthcare professional on the basis of his or her professional licence, experience and knowledge of the patient. Healthcare professionals must rely on their judgment when deciding which treatments and procedures to use with patients.

 All images are the property of Boston Scientific. All trademarks are the property of their respective owners.

 Individual symptoms, situations, circumstances and results may vary. This website is meant for information purposes only, it is not intended to be used for medical diagnosis or treatment or as a substitute for professional medical advice. We may also include certain information, reference guides and databases intended for use by licensed medical professionals. These are not intended to give professional medical advice. Physicians and other health care providers should always exercise their own clinical judgment for any given situation. Boston Scientific does not promote or encourage the use of its devices outside of their approved labeling. Please consult your doctor or qualified healthcare provider regarding your condition and appropriate medical treatment. 

 This site is intended for Healthcare Professionals only. Please review the Boston Scientific Privacy Policy  for practices on the collection, storage, use and disclosure of your personal information.

 Videos provided are meant for informational purposes only and may not be indicative of actual size or clinical outcome. The opinions, procedures and patient care policies expressed or depicted in videos are those of the physician and do not necessarily reflect the opinions, policies or recommendations of Boston Scientific Corporation or any of its employees. For further information and detailed instructions regarding the use of the Boston Scientific products featured in this video, please refer to the directions for use included within the Boston Scientific product package.

Reference:

1. M. Matsumura, et al. JACC: Advances. "Accuracy of IVUS-Based Machine Learning Segmentation Assessment of Coronary Artery Dimensions and Balloon Sizing." 2023. https://doi.org/10.1016/j.jacadv.2023.100564