DYNAGEN™ MINI ICD

The world’s smallest and thinnest ICD.1

DYNAGEN™ MINI ICD - Model DR and VR
DYNAGEN™ MINI ICD - Model DR
DYNAGEN™ MINI ICD - Model VR

Boston Scientific provides devices tailored to individual needs. Up to 20% smaller and 24% thinner than other ICDs on the market2, the MINI offers all the power of a Boston Scientific ICD in a device that is the industry’s sleekest2 and designed for patient comfort.

Key Resources

Explore

 

Product Details

Models D020, D021, D022, and D023

  • The world’s smallest and thinnest2 high-energy ICD designed to enhance patient comfort.

  • Includes the new EasyView™ header with color coded lead ports, designed to improve implant efficiency.

  • Offers an uncompromised set of features including:

- An advanced system solution for patient comorbidities and HF monitoring (HF Perspectiv™ report, LATITUDE™ NXT Remote Patient Management* enabled with weight scale and blood pressure sensors, and Respiratory Rate Trend).

- AcuShock™ Advanced Technology, multiple programmable options to reduce inappropriate and unnecessary shocks, including a choice of rhythm discriminators, antitachycardia pacing (ATP) therapy in all rates zones, and advanced sensing and filtering.

- RhythmID™ with RhythmMatch™ feature to allow customization of Rhythm ID algorithm to reduce inappropriate shocks.

- AV Search+ and RYTHMIQ™ which gives clinicians options to appropriately manage RV pacing in patients with varying degrees of conduction block.

- Wireless ECG to save time and simplify follow-up.

- SafetyCore™ technology intended to provide lifesaving shock therapy and basic pacing functionality in the event of an unrecoverable fault.

Mechanical Specifications

ModelTypeSize (cm)
(W x H x D)
Mass
(g)
Volume
(cm3)
Connector Type
(RA RV LV)
D020VR5.23 x 6.71 x 0.9960.026.5RV:DF4
D022DR5.23 x 7.03 x 0.9962.528.0RA:IS-1;RV:DF4
D021VR5.23 x 7.14 x 0.9961.928.5RV:IS-1/DF–1
D023DR5.23 x 7.14 x 0.9962.328.5RA:IS-1;RV:IS-1/DF–1
Source: Physician's Technical Manual

Pulse Generator Projected Longevity (All DYNAGEN MINI ICD Models a,b,c,d)

 Longevity (years) at 500Ω, 700Ω, and 900Ω Pacing Impedance (RV)
 500Ω700Ω900Ω
PacingVRDRVRDRVRDR
0%5.55.35.55.35.55.3
15%5.45.15.45.15.55.1
50%5.24.75.34.75.34.8
100%4.94.25.04.35.14.4
a Assumes ZIP™ telemetry use for 1 hour at implant time and for 40 minutes annually for in-clinic follow-up checks.
b Assumes standard use of the LATITUDE™ Communicator as follows: Daily Device Check on, monthly Full Interrogations (scheduled remote follow ups, and quarterly patient-interrogations).
c Assumes 60 bpm LRL, ventricular and atrial settings of 2.5 V pacing pulse Amplitude and 0.4 ms pacing pulse width; RA Impedance 500 ; sensors On.
d Projected longevity is calculated assuming 3 maximum energy charging cycles per year, including automatic capacitor re-forms and therapeutic shocks. For the final year of device service, an additional 5 charging cycles
are assumed to account for additional automatic capacitor re-forms as the device approaches the Explant indicator. These calculations also assume 3-channel EGM Onset is set to On,and that the pulse generator spends
6 months in Storage mode during shipping and storage.

Longevity Information

  • For longevity calculations based on different settings please contact Boston Scientific technical services or your local representative.

  • Boston Scientific devices have a limited product warranty of 5 years (VR and DR) in available geographies. See www.bostonscientific.com/cardiac-rhythm-resources for complete warranty terms and conditions.

  • Devices use Li/MnO2 battery chemistry.

  • The usable battery capacity is 1.0 Amp-hours for the MINI ICD (typical implant to battery capacity depleted).

  • Shelf life is 2 years (before use by date).

Longevity projections as provided in the product labeling. Specific programmable parameter ranges available in product labeling. Product labeling available at https://www.BostonScientific/cardiac-rhythm-resources/instructions for use.html

Source: Physician's Technical Manual


Top