Captivator™ II

Single-Use Snare

The rounded shape of the Captivator II snare is designed to capture flat lesions and has a shorter distance from the scope to facilitate tip control and visualization.
Provides a variety of size options to help manage different polyp types
Smaller loop options help with the removal of diminutive polyps and the resection of residual tissue during EMR
The stiff braided wire design provides grip and traction on flat polyps and allows for wire control.
All of Boston Scientific’s snares are now indicated for both cold and hot polypectomy.

The Captivator II Snares are the first line of stiff and rounded snares. A variety of size options help manage different polyp types.

Explore

Product Details

The Captivator II Snare line provides a variety of size options to help manage different polyp types such as large or flat lesions, lesions on the right-side of the colon and lesions on a colonic fold.

The Captivator II Snares are the first line of stiff and rounded snares, available in multiple sizes with both a hot and cold snaring indication.

Features include:                    

  • Stiff Snare
  • Rounded Shape
  • Braided Wire
  • Hot/Cold Indication
  • Smaller Loop Options

 

For more information on product, please download our product brochure.
Captivator II Single-Use Snare
Captivator II Single-Use Snare

Order Number

Description

Loop width (mm)

Sheath O.D. (mm)

Minimum Working Channel (mm)

Working Length (cm)

Units

M00561191

25mm Rounded- Stiff

25

2.4

240

2.8

Box 10

M00561221

10mm Rounded - Stiff

10

2.4

240

2.8

Box 10

M00561231

15mm Rounded -Stiff

15

2.4

240

2.8

Box 10

M00561241

20mm Rounded -Stiff

20

2.4

240

2.8

Box 10

M00561291

33mm Rounded -Stiff

33

2.4

240

2.8

Box 10


Case Study: Endoscopic Mucosal Resection (EMR)

Presented by David A. Florez, MD (USA)

This case demonstrates the management of large polyps utilizing the Captivator II Snare.  The large diameter aperture of the snare allows for complete en-bloc resection of the polyp with one pass.

Read Case Study ›

Additional Devices Used in This Case Study

    Resolution™ Clip ›

 
Top