CRE™ Balloon Dilators

play icon
RO markers are available on most wireguided CRE Balloons to aid in visualization and placement.
Rounded shoulders designed to facilitate visualization of stricture while dilating
Designed to produce three distinct diameters at three separate pressures during in vivo dilation.
Alliance II Inflation System
Animation of Balloon Endoscopy with the CRE Wireguided Balloon Dilator.

CRE Fixed and Wireguided Balloon Dilators provide consistent performance for Balloon Endoscopy for optimal control, efficiency and technology. Also available for use in the Dilation Assisted Stone Extraction (DASE) procedure.

Key Resources

Explore

Product Details

Ordering Information

CRE Single-Use Fixed Wire Esophageal Balloon Dilators
CRE Single-Use Fixed Wire Esophageal Balloon Dilators
Order NumberBalloon Inflated O.D. (mm)Balloon Inflated O.D. (Fr)Balloon Length (cm)Inflation Pressures (ATM)Inflation Pressures (kPa)Minimum Working Channel (mm)Catheter Size (Fr)Working Length (cm)Packaging
M005583306-7-818-21-2483-6-10304-608-10132.86180Each
M005583408-9-1024-27-3083-5.5-9304-557-9122.86180Each
M0055835010-11-1230-33-3683-5-8304-507-8112.86180Each
M0055836012-13.5-1536-40.5-4583-4.5-8304-456-8112.86180Each
M0055837015-16.5-1845-49.5-5483-4.5-7304-456-7092.86180Each
M0055838018-19-2054-57-6083-4.5-6304-456-6082.86180Each

 

  Recommended Inflation Device: Alliance™ II Integrated Inflation System Handle Order #5062, Sterile Syringe Order #5060 (See below)
CRE Single-Use Wireguided Esophageal / Pyloric Balloon Dilators
Order NumberBalloon Inflated O.D. (mm)Balloon Inflated O.D. (Fr)Balloon Length (cm)Inflation Pressures (ATM)Inflation Pressures (kPa)Minimum Working Channel (mm)Catheter Size (Fr)Working Length (cm)Packaging
M005583906-7-818-21-245.53-6-10304-608-10132.87.5180Each
M005584008-9-1024-27-305.53-5.5-9304-557-9122.87.5180Each
M0055841010-11-1230-33-365.53-5-8304-507-8112.87.5180Each
M0055842012-13.5-1536-40.5-455.53-4.5-8304-456-8112.87.5180Each
M0055843015-16.5-1845-49.5-545.53-4.5-7304-456-7092.8 / 3.2*7.5180Each
M00558440**18-19-2054-57-605.53-4.5-6304-456-6082.8 / 3.2*7.5180Each

Recommended Inflation Device: Alliance™ II Integrated Inflation System Handle Order #5062, Sterile Syringe Order #5060. (See below)

Guidewire included and preloaded in balloon catheter.

*Requires a 2.8mm Olympus™ Brand Endoscope channel or a 3.2mm Pentax™ or Fujinon™ Brand Endoscope channel.

**Esophageal application only.

CRE Single-Use Wireguided Esophageal / Pyloric / Colonic Balloon Dilators
Order NumberBalloon Inflated O.D. (mm)Balloon Inflated O.D. (Fr)Balloon Length (cm)Inflation Pressures (ATM)Inflation Pressures (kPa)Minimum Working Channel (mm)Catheter Size (Fr)Working Length (cm)Packaging
M005584506-7-818-21-245.53-6-10304-608-10132.8/ 3.2*7.5240Each
M005584608-9-1024-27-305.53-5.5-9304-557-9122.8 / 3.2*7.5240Each
M0055847010-11-1230-33-365.53-5-8304-507-8112.8 / 3.2*7.5240Each
M0055848012-13.5-1536-40.5-455.53-4.5-8304-456-8112.8 / 3.2* 7.5240Each
M0055849015-16.5-1845-49.5-545.53-4.5-7304-456-7092.8 / 3.2*7.5240Each
M00558500**18-19-2054-57-605.53-4.5-6304-456-6082.8 / 3.2*7.5240Each

Recommended Inflation Device: Alliance™ II Integrated Inflation System Handle Order #5062, Sterile Syringe Order #5060. (See below)

Guidewire included and preloaded in balloon catheter.

*Requires a 2.8mm Olympus™ Brand Endoscope channel or a 3.2mm Pentax™ or Fujinon™ Brand Endoscope channel.

**Esophageal or Colonic application only.

Alliance™ II Inflation System
Order NumberDescriptionPackaging
M00550620Inflation HandleEach
M00550601Single-Use Syringe / Gauge AssemblyBox 5
CRE Single-Use Wireguard Balloon Dilators

Order No

Inflated O.D. (mm)

Balloon length (cm)

Inflation Pressures

Catheter
diameter (F)/(mm)

Working Length (cm)

 

 

 

ATM

kPa

 

 

Esophageal, Pyloric and Biliary

M00558390

6-7-8

5.5

3-6-10

304-608-1013

7.5/2.5

180

M00558400

8-9-10

5.5

3-5.5-9

304-558-912

7.5/2.5

180

M00558410

10-11-12

5.5

3-5-8

304-507-810

7.5/2.5

180

M00558420

12-13.5-15

5.5

3-4.5-8

304-456-810

7.5/2.5

180

M00558430

15-16.5-18

5.5

3-4.5-7

304-456-709

7.5/2.5

180

M00558440

18-19-20

5.5

3-4.5-6

304-456-608

7.5/2.5

180

Esophageal, Pyloric, Colonic and Biliary

M00558450

6-7-8

5.5

3-6-10

304-608-1013

7.5/2.5

240

M00558460

8-9-10

5.5

3-5.5-9

304-558-912

7.5/2.5

240

M00558470

10-11-12

5.5

3-5-8

304-507-810

7.5/2.5

240

M00558480

12-13.5-15

5.5

3-4.5-8

304-456-810

7.5/2.5

240

M00558490

15-16.5-18

5.5

3-4.5-7

304-456-709

7.5/2.5

240

M00558500

18-19-20

5.5

3-4.5-6

304-456-608

7.5/2.5

240


CRE Single-Use Fixed wire Balloon Dilators

Order No

Inflated O.D. (mm)

Balloon length (cm)

Inflation Pressures

Minimum working channel (mm)

Catheter diameter (F)/(mm)

Working Length (cm)

 

 

 

ATM

kPa

 

 

 

M00558330

6-7-8

8

3-6-10

304-608-1013

2.8

6/2.00

180

M00558340

8-9-10

8

3-5.5-9

304-557-912

2.8

6/2.00

180

M00558350

10-11-12

8

3-5-8

304-507-810

2.8

6/2.00

180

M00558360

12-13.5-15

8

3-4.5-8

304-456-810

2.8

6/2.00

180

M00558370

15-16.5-18

8

3-4.5-7

304-456-709

2.8

6/2.00

180

M00558380

18-19-20

8

3-4.5-6

304-456-608

2.8

6/2.00

180

Case Studies

Read Additional Case Studies:

     Treatment of Abdominal Pain and an Ileocolonic Anastomotic Stricture with a CRE Balloon

Presented by Dr. Luis F. Lara (USA)

     Distal Esophageal Peptic Stricture Treated with a CRE Wireguided Balloon Dilator

Presented by Dr. Fadlallah Habr (USA)

Related Procedure

Top