Habib™
EndoHPB Bipolar Radiofrequency Catheter
The Habib™ EndoHPB Catheter is the first Radio Frequency (RF) ablation catheter indicated in Europe for malignant or benign tissue ablation in the pancreatic and biliary tract.
When surgery is not an option for patients with difficult-to-treat cancers, the Habib™ EndoHPB Catheter enables you to perform:
• Partial or complete ablation of malignant or benign tissue in the pancreatic and biliary tracts.
• Endoscopic biliary drainage or decompression prior to stent placement or afterwards to clear an occluded stent.
Endoscopic biliary RF ablation with the HabibTM EndoHPB Catheter may provide prolonged stent patency. One study has shown prolonged metallic biliary stent patency by an average of 13% (from 8.4 months to 9.5 months)1 in patients with unresectable extrahepatic cholangiocarcinoma.
Key Resources
Product Details
Device Specification | Intended Benefits |
---|---|
180cm useable length, 8Fr (2.7mm) diameter | Enables biliary access through a 3.2mm working channel duodenoscope |
2, 8mm stainless steel ring electrodes | Produce ablation depths 3-4mm from the wall of the catheter. Resulting ablation zone is 25mm ± 3mm long by 9mm ± 2mm wide (1) |
Compatible with commonly available RF generators and endoscopes with a working channel of 3.2mm or greater | Does not require the purchase of dedicated capital equipment |
Bipolar RF Device | Use of adapter cable enable bipolar RF ablation and avoids the need for electrode grounding pads |
Features and Benefits
- Treatment alternative that may prolong patency and restore biliary drainage1
- The Habib EndoHPB Catheter may provide an option to restore biliary drainage in patients who may outlive the patency of their metallic biliary stents.2
- Clinical data from one study suggests that RFA with the Habib EndoHPB Catheter for occluded SEMS may improve mean stent patency time compared to plastic stent insertion.2
Minimal Capital Investment
The Habib™ EndoHPB Catheter is compatible with many commonly available electrosurgical generators and endoscopes with a working channel of 3.2mm or greater, eliminating the unique capital expenditure. There is also no need for electrode grounding pads when using our adaptor cable.
UPN | Description | Generator |
---|---|---|
M00500070 | EndoHPB Bipolar Radiofrequency Catheter | N/A |
5100 | Adapter Cable Bipolar, 28mm pins | KLS Maxium, Olympus ESG-100 |
5420 | Adapter Cable Bipolar, Internal 4 mm pin | Erbe ICC200, ICC300, ICC355, Erbe Vio 200 or 300 (D/S) Genii GI 4000 |
5700 | Adapter Cable Bipolar, 22 mm Spacing | Erbe ICC200, ICC300, ICC355, Erbe Vio 200 or 300 (D/S) |
Ease of Use
- No need for dedicated capital equipment
- Compatible with most electrosurgical generators
- Simple time and power algorithm delivers consistent results3
- One probe size, each ablation produces an ablation zone approximately 25mm x 3.5mm deep (at 10W, 90s).3
Ordering Information
Product Number | Product Description | Specifications |
---|---|---|
M00500070 | Habib EndoHPB Bipolar RF Catheter (180cm, 8F) | Single-Use |
5420 | Bipolar Adapter Cable | Reusable |
5100 | Bipolar Adapter Cable | Reusable |
5420 | Bipolar Adapter Cable | Reusable |
5700 | Bipolar Adapter Cable | Reusable |
Contact Information and Ordering
For product orders or complaints, please contact: 1-888-272-1001

REFERENCES
1. Liang, H. et al, “Metal Stenting with or without Endobiliary Radiofrequency Ablation for Unresectable Extrahepatic Cholangiocarcinoma”, Journal of Cancer Therapy, October 2017.
2. Kadayifci A. et al., Endoscopy 2016;48:1096-1101
3. DN VAL-R-020